Specification
Standard Pull Cord Length 160mm.
Other Pull Cord lengths available at an extra cost.
Our Inflators are available with either ‘D’ or ‘O’ manifold fixing attachments.
Assembly (Body and Capsule)
UMA800-8050: PSE Auto D Assembly 0.5 inch UNF 160mm
UMA8010-8050: PSE Auto O Assembly 0.5 inch UNF 160mm
Capsule Only
• UMA8050 PSE Capsule
Standard automatic water-activated capsule fitted to the bottom of the PSE Head.
This contains no indicators or components that fall away.
Caps
• UMA8090 Blanking Cap
This empty capsule can be fitted instead of the standard capsule. This is a
longerlonger-term way to make the PSE manual manual-only than the sealing cap above.
Product description
The Pro Sensor Elite® Automatic Inflator replaces the Pro Sensor® Automatic Inflator. Being 13mm shorter and 4 grams lighter than the original Pro Sensor® Automatic Inflator the Elite Inflator range also benefits from a more rounded design and improved manual lever retention.
The Pro Sensor Elite® Automatic Inflator provides additional improvement on the standard MK5 Automatic Inflator, affording the user one point of status indication to confirm that the unit has been automatically or manually activated. The unit also provides the added benefit of detecting if the Co² cylinder has been pierced, eradicating the possibility of accidentally fitting an empty gas cylinder.
As with the UML MK5 Inflator the great benefit of this inflation system is the functionality of the automatic override which under normal operating conditions activate within 3 seconds of the system being submerged in water. The automatic capsule contains a powerful spring which is compressed and retained in place using a paper element.
Once the paper element becomes wet, it releases the spring which pushes a plunger forward enabling a cutter to pierce the Co² gas cylinder. The Co² gas from the cylinder instantly passes through the inflator head, inflating the lifejacket.
The product is independently approved in accordance with the ISO12402 Part 7 standard requirement for lifejackets.
The units are available on demand, with re-charge kits being stocked by most distributors of marine products. Note: – UML only supply to trade customers.
For the Manifold Fixing and Oral Tube as well as Spares & Technical Data, please use the Contact Us facility below.
Checking the Pro Sensor Elite Elite ® Automatic Capsule Replace By Date
The UML Pro Sensor Elite Automatic Capsule has a Replace By Date printed on it, replace before this date.
I.e. on the capsule is shown: REPLACE BY 10 2025 A = Replace By Month/Year (October 2025). Note the Letter printed at the end of the Year is not relevant to the serviceable date.
Recreational Use: Replace every two years or by the REPLACE BY date whichever is sooner. It is recommended your lifejacket is inspected annually. Refer to your lifejacket manual and keep to service intervals.
Commercial/Professional Use: Replace annually. Do not exceed the REPLACE BY date in any 1-year period. SOLAS approved life jackets are required to be serviced by an authorised service station annually.
The Pro Sensor Elite Automatic Inflator indication is only fully operational when both green indicators are showing fully and water is not restricted to the Capsule Firing Mechanism.

The CO2 cylinder must be checked each time you don your lifejacket to ensure it is tightly screwed in by hand. In addition, the cartridge must be checked to ensure it has not passed the replace by date and is also fully screwed on tightly by hand.
The top indicator identifies the CO2 cylinder status. Red indicates it is missing or has been pierced. Partially red indicates the CO2 cylinder is not screwed in fully or has been partially pierced.
REMOVE THE CYLINDER AND ENSURE IT FULL AND HAS NOT BEEN PIERCED BEFORE SCREWING BACK IN HAND TIGHT.
The bottom indication identifies the Automatic Firing Mechanism status. Red indicates it is missing or has been activated. Partially red indicates the Automatic Firing Mechanism is not screwed on fully.
BOTH INDICATIONS MUST BE FULLY SHOWING GREEN, THE CAPSULE IS WITHIN ITS PRINTED REPLACE BY DATE AND WITH A FULL CO2 CYLINDER SCREWED IN HAND TIGHT FOR CORRECT OPERATION.
How the Indication System Works
This product provides additional improvement on the standard MK5, affording the user one point of status indication, to confirm that the unit has been automatically or manually activated. The unit also provides the added benefit of detecting if the CO2 cylinder has been pierced, eradicating the possibility of accidentally fitting an empty gas cylinder.
The Pro Sensor Elite® Automatic Inflator is only fully operational when both green indicators are fully showing green, water is not restricted to the Cartridge Firing Mechanism, the Automatic Cartridge is within its printed Replace By Date and a fully screwed in full CO2 Cylinder in place.
The indication system on the Pro Sensor Elite® Automatic Inflator allows the user to establish if the system has been fired including the added benefit of quickly identifying if a pierced CO2 cylinder is accidentally refitted to the inflator during the servicing procedure.

The Pro Sensor Elite® Automatic Inflator indication is only fully operational when both green indicators are showing fully and water is not restricted to the Capsule Firing Mechanism.